Select your language

Product Fillter

MODEL: DIS

MODEL: DIS-90/DIS-252/DIS-501

Scroll Type Dry Vacuum Pump

Scroll type dry vacuum pumps are dry vacuum pumps that exhaust air by combining the movements of a scroll-type stator and rotor.
They are used in a wide range of fields, including vacuum drying equipment, physicochemical analysis equipment, vacuum suction transport equipment, and vacuum heat treatment furnaces.

Image

Features

  • Compact size with large displacement.
  • The highest level of ultimate pressure for dry vacuum pumps.
  • Safety design with built-in automatic reset type thermal protector.
  • Suppresses moisture condensation by air flush.

Applications

  • Analytical equipment.
  • Gas recovery system.
  • Coating equipment.
  • Back pump for TMP.
  • Helium leak detector.
  • Manufacturing process for semiconductor.
    Unit DIS-90 DIS-252 DIS-501
50Hz 60Hz 50Hz 60Hz 50Hz 60Hz
Actual pumping speed※1   L/min 90 108 250 300 500 600
Ultimate pressure   Pa (kPa) 5 1.6 1
Motor※2

Single Phase

A

100/115/200/230V, 150W, 4P Capacitor start/run 100/115/200/230V, 400W, 4P Capacitor start/run 100/115/200/230V, 600W, 4P , Capacitor start/run
Three Phase - 200/208/230/380/400/415/460V, 400W, 4P 200/208/230/380/400/415/460V, 600W, 4P
Full load current

Single Phase

A 2.6/1.3/1.6
(100/200/230V)

2.1/2.2/1.1/1.1
(100/115/200/230V)

4.8/2.6/2.4
(100/200/230V)
4.8/4.3/2.8/2.4
(100/115/200/230V)
8.5/4.3/3.9
(100/200/230V)
10.0/8.6/4.8/4.0
(100/115/200/230V)
Three Phase - - 1.6/0.9/0.9/1.0
(200/300/400/415V)
1.9/1.9/1.8/1.0
(100/115/200/230V)
2.7/1.57/1.57/1.63
(200/380/400/415V)
2.8/2.6/2.5/1.47
(200/208/230/460V)
Weight

Single Phase

kg 14 25 44
  Three Phase - 23 38
Inlet, Outlet port diameter    mm KF-25 / KF-16 KF-40 / KF-25
Ambient temperature   deg. C 5 - 40
External dimensions

Single Phase

mm 214(W) X 308(L) X 225(H) 252(W) X 400(L) X 336(H) 290(W)×443(L)×397(H)
  Three Phase - 252(W) X 370(L) X 336(H) 292(W) X 372(L) X 397(H)

※1:Actual pumping speed is about 1.2 times the Actual pumping speed when a gas at atmospheric pressure is sucked.
※2:Power supply plug and Power supply code are not included.
※3:AF=Air flush
The air flush operation not only discharges the water remaining in the pump, but also has the effect of recovering the Ultimate pressure.

 

Corresponding certificate/Voltage

Model Applicable standard CEDeclartion of confirmity
100V

200V

200V

400V
DIS-90 cTUV
(Can be switched by changing the terminal plate)
DIS-252 cTUV
(Can be switched by changing the terminal plate)

(Can be switched by changing the terminal plate)
DIS-501 cTUV
(Can be switched by changing the terminal plate)

(Can be switched by changing the terminal plate)
✓:Standard, ○:Option, -:Not Applicable
cTUV certification: This is a high quality product that complies with Canadian standards, as assessed by an international third party that conducts product safety testing and certification.
 

Caution

  1. If the pump evacuates the powder or the product, it might be damaged. Please use the inlet filter etc.
  2. Do not evacuate gas which is hazardous to humans or explosive, flammable, or corrosive. If done, it can cause failure by gas, explosion or ignite.
  3. The Three phaseSpecification does not have motor protection.Be sure to install a protective device such as an earth leakage circuit breaker.

Single Phase

Dimension drawing

⏹︎ DIS-90

Image

⏹︎ DIS-252

Image

⏹︎ DIS-501

Single Phase

Image

Three Phase

Image

Dimension drawing

⏹︎ DIS-90

Image

⏹︎ DIS-252

Image

⏹︎ DIS-501

Image