| Model |
Unit |
DISL-102 |
DISL-503 |
| 50Hz |
60Hz |
50Hz |
60Hz |
| Actual pumping speed |
L/min |
100 |
120 |
433 |
516 |
| Ultimate pressure |
Pa |
20 |
30 |
| Motor※ |
|
Single phase, 100/115/200/230V, 300W, 2P, Capacitor start/run |
Three phase, 200/380/400/415V/900W, 2P |
Three phase, 200/220/230/460V, 1,100W, 2P |
| Full load current |
A |
2.6/1.3/1.4 |
2.9/2.8/1.6/1.4 |
3.7/1.88/1.87/1.88 |
4.1/3.9/3.85/1.92 |
| (100/200/230V) |
(100/115/200/230V) |
(200/380/400/415V) |
(200/380/400/415V) |
| Weight |
kg |
17 |
34 |
| Inlet flange |
|
KF-25 |
KF-25(Rc1/2) |
| Outlet pipe diameter |
|
KF-16 |
KF-25 |
| Ambient temperature |
deg. C |
5 - 40 |
| Water vapor handing |
g/day |
100 (※AF open) |
250 (※AF open) |
| External dimensions |
mm |
221(W)×380(L)×218(H) |
317(W) X 521(L) X 280(H) |
※:Power supply plug and Power supply code are not included.
※:AF=Air flush
The air flush operation not only discharges the water remaining in the pump, but also has the effect of recovering the Ultimate pressure.
Corresponding certificate/Voltage
✓:Standard, ○:Option, -:Not Applicable
※cTUV certification: This is a high quality product that complies with Canadian standards, as assessed by an international third party that conducts product safety testing and certification.
Caution
- If the pump evacuates the powder or the product, it might be damaged.Please use the inlet filter etc.
- Do not evacuate gas which is hazardous to humans or explosive, flammable, or corrosive. If done, it can cause failure by gas, explosion or ignite.
- This product has no motor protection function.Be sure to install a protective device such as an earth leakage circuit breaker.