Unit |
DIS-90 |
DIS-252 |
DIS-501 |
| 50Hz |
60Hz |
50Hz |
60Hz |
50Hz |
60Hz |
| Actual pumping speed※1 |
|
L/min |
90 |
108 |
250 |
300 |
500 |
600 |
| Ultimate pressure |
|
Pa (kPa) |
5 |
1.6 |
1 |
| Motor※2 |
Single Phase
|
A
|
100/115/200/230V, 150W, 4P Capacitor start/run |
100/115/200/230V, 400W, 4P Capacitor start/run |
100/115/200/230V, 600W, 4P , Capacitor start/run |
| Three Phase |
- |
200/208/230/380/400/415/460V, 400W, 4P |
200/208/230/380/400/415/460V, 600W, 4P |
| Full load current |
Single Phase
|
A |
2.6/1.3/1.6 (100/200/230V) |
2.1/2.2/1.1/1.1 (100/115/200/230V)
|
4.8/2.6/2.4 (100/200/230V) |
4.8/4.3/2.8/2.4 (100/115/200/230V) |
8.5/4.3/3.9 (100/200/230V) |
10.0/8.6/4.8/4.0 (100/115/200/230V) |
| Three Phase |
- |
- |
1.6/0.9/0.9/1.0 (200/300/400/415V) |
1.9/1.9/1.8/1.0 (100/115/200/230V) |
2.7/1.57/1.57/1.63 (200/380/400/415V) |
2.8/2.6/2.5/1.47 (200/208/230/460V) |
| Weight |
Single Phase
|
kg |
14 |
25 |
44 |
| |
Three Phase |
- |
23 |
38 |
| Inlet, Outlet port diameter |
|
mm |
KF-25 / KF-16 |
KF-40 / KF-25 |
| Ambient temperature |
|
deg. C |
5 - 40 |
| External dimensions |
Single Phase
|
mm |
214(W) X 308(L) X 225(H) |
252(W) X 400(L) X 336(H) |
290(W)×443(L)×397(H) |
| |
Three Phase |
- |
252(W) X 370(L) X 336(H) |
292(W) X 372(L) X 397(H) |
※1:Actual pumping speed is about 1.2 times the Actual pumping speed when a gas at atmospheric pressure is sucked.
※2:Power supply plug and Power supply code are not included.
※3:AF=Air flush
The air flush operation not only discharges the water remaining in the pump, but also has the effect of recovering the Ultimate pressure.
Corresponding certificate/Voltage
✓:Standard, ○:Option, -:Not Applicable
※cTUV certification: This is a high quality product that complies with Canadian standards, as assessed by an international third party that conducts product safety testing and certification.
Caution
- If the pump evacuates the powder or the product, it might be damaged. Please use the inlet filter etc.
- Do not evacuate gas which is hazardous to humans or explosive, flammable, or corrosive. If done, it can cause failure by gas, explosion or ignite.
- The Three phaseSpecification does not have motor protection.Be sure to install a protective device such as an earth leakage circuit breaker.